Main Unit:
Principle:
Transit-time
Accuracy:
Flow meter: ±1.0%; Heat meter: ±2.0%
Output:
4-20mA analog output
OCT pulse output
Relay output
Input:
3-way 4-20mA analog input, acquiring temperature, pressure, and liquid level signals
Achieve heat measurement by connecting PT100 temperature sensors
Interface:
RS485; MODBUS
Pipeline:
Pipe Material:
Steel, stainless steel, cast iron, copper, cement, PVC, aluminum, glass steel, etc.
Caliber:
DN15mm-DN1000mm
Straight Pipeline:
Upstream: 10D; Downstream: 5D; From the pump: 30D (D means diameter)
Measuring Medium:
Medium:
Single liquid that can conduct sound waves, such as water (-30℃-160℃)
Velocity:
-12m/s to 12m/s
Special Cable:
Shielded twisted-pair cable, length ≤ 50m
Temperature:
Main Unit: -20℃-70℃; Transducer: -30℃-160℃
Protection Class:
Main Unit: IP67; Transducer: IP68
Power Supply:
DC24V; AC85-264V; 50Hz
Consumption:
1.5W