“The PHOENIX Radar Flowmeter” is a product from Flow Tronic company. This product is suitable for wide channels and rivers. In the software of this flowmeter, it is easy to draw the shapes of channel cross-sections, whether geometric or irregular sections, such as the natural bed of a river, and define them in the system.

However, we all know that the simpler the geometric shape of the cross-section, the easier the work and the higher the accuracy. Therefore, the selection of sensor installation locations is crucial, considering both the top (avoiding excessive sedimentation) and the bottom.

It is worth mentioning that AbSanj Mehr is the exclusive representative of Flow Tronic, Belgium and also we have successfully installed and operated numerous cases of this radar flowmeter to this date.

شروع قیمت از :

Loading...
  • Continuous measurement of river flow rates even in flood conditions
  • Easy installation on bridges or any structure existing over the river
  • Sensor installation angle of 60 degrees and high beam angle (32 degrees horizontal and 14 degrees vertical)
  • Installing the sensor at the minimum distance from the water surface, up to a maximum of 30 meters, depending on the water surface conditions
  • Measurement range of velocity: 9 to 15.0 m/s
  • Very durable body with IP68 protection rating
  • Internal flow processing and 20-4 mA output

General Specifications
Velocity Measurement
Method Radar
Type Continuous Wave Doppler
Range ±0,10 to ±15 m/s (depending on flow conditions)
(bi-directional / flow direction detection)
Frequency 24,125 GHz (K-Band)
Accuracy ±1%
Resolution 1 mm
Distance to water 0,50 … 35 m
Radar Opening Angle
Opening angle 32°
Installation angle 60°
Power
Supply 4 to 26 VDC
Consumption 1,38 W (during active measurement)
Level Measurement (Radar)
Method Radar
Range 0,01 to 15 m (standard range)
0,01 to 35 m (extended range)
Accuracy ±2 mm of reading
Resolution 1 mm
Operation temp. -40 … +70 °C
Frequency 26 GHz (K-Band)
Optional Separate Level Measurement
Method Any 4-20 mA loop powered sensor
Communication
Modbus RS-485 communications port with Modbus ASCII slave communication protocol
Outputs (optional)
4-20 mA 1 for validated surface velocity (vQP) or validated surface velocity including median filter (vQPMF)
Material & Dimensions
Dimensions 166 mm H x 157 mm W x 178 mm L
Weight 2,60 kg
Material Robust PU
Protection IP68
Color Grey
Environmental Conditions
Operating temperature range -30° to 70° C
Storage temperature range -40º to 80º C
Certifications
CE

  • Monitoring river, canals and natural streams flow
  • Water management
  • Flood prevention
  • Monitoring irrigation channel flow
  • Hydropower plants
  • Rain basin modeling
  • Large sewage channels
  • Drainage systems

Catalog

Phoenix Quick Form
Filling in the fields marked in red is mandatory.

Company Name
Last Name
First Name
Explanations
Phone Number
Email Address

Source of energy
Data Logger
Level Sensor
Sensor Cable
Accessories

Submit
Please review the above before submitting.

Loading...
  • Continuous measurement of river flow rates even in flood conditions
  • Easy installation on bridges or any structure existing over the river
  • Sensor installation angle of 60 degrees and high beam angle (32 degrees horizontal and 14 degrees vertical)
  • Installing the sensor at the minimum distance from the water surface, up to a maximum of 30 meters, depending on the water surface conditions
  • Measurement range of velocity: 9 to 15.0 m/s
  • Very durable body with IP68 protection rating
  • Internal flow processing and 20-4 mA output

General Specifications
Velocity Measurement
Method Radar
Type Continuous Wave Doppler
Range ±0,10 to ±15 m/s (depending on flow conditions)
(bi-directional / flow direction detection)
Frequency 24,125 GHz (K-Band)
Accuracy ±1%
Resolution 1 mm
Distance to water 0,50 … 35 m
Radar Opening Angle
Opening angle 32°
Installation angle 60°
Power
Supply 4 to 26 VDC
Consumption 1,38 W (during active measurement)
Level Measurement (Radar)
Method Radar
Range 0,01 to 15 m (standard range)
0,01 to 35 m (extended range)
Accuracy ±2 mm of reading
Resolution 1 mm
Operation temp. -40 … +70 °C
Frequency 26 GHz (K-Band)
Optional Separate Level Measurement
Method Any 4-20 mA loop powered sensor
Communication
Modbus RS-485 communications port with Modbus ASCII slave communication protocol
Outputs (optional)
4-20 mA 1 for validated surface velocity (vQP) or validated surface velocity including median filter (vQPMF)
Material & Dimensions
Dimensions 166 mm H x 157 mm W x 178 mm L
Weight 2,60 kg
Material Robust PU
Protection IP68
Color Grey
Environmental Conditions
Operating temperature range -30° to 70° C
Storage temperature range -40º to 80º C
Certifications
CE

  • Monitoring river, canals and natural streams flow
  • Water management
  • Flood prevention
  • Monitoring irrigation channel flow
  • Hydropower plants
  • Rain basin modeling
  • Large sewage channels
  • Drainage systems

Catalog

Phoenix Quick Form
Filling in the fields marked in red is mandatory.

Company Name
Last Name
First Name
Explanations
Phone Number
Email Address

Source of energy
Data Logger
Level Sensor
Sensor Cable
Accessories

Submit
Please review the above before submitting.

سوالی دارید و یا به پشتیبانی نیاز دارید؟