General Specifications
PHYSICAL
Sensor Body Dimensions: 90 mm D x 140 mm H (3.5 in x 5.5 in)
Weight: Nominal 1 kg (2.2 lb)
Sensor Body Material/
Description: Valox 357
Transducer Cable
Extensions: 5-core screened
Maximum Separation: Up to 500 m (1,640 ft)
Mounting Connection: Via 1” BSP back-mounted thread or 20 mm (0.8 in) via the supplied adaptor. Optional mounting bracket available from
Pulsar
Mounting Angle: 45° optimal and mounted at the centerline of the channel with a clear uninterrupted view
ENVIRONMENTAL
Enclosure Protection: IP68
Max. & Min. Temperature
(Electronics): -20 °C to +60 °C (-4 °F to +140 °F)
CE & Radar Approvals: Listed in the Certificate of Conformity within the manual.
ATEX Approval: Ex II 2 G D, Ex mb IIC T4 Gb, Ex mb IIIC T135 °C Db, Ta= -20 °C to +60 °C
PERFORMANCE
Velocity Range: 200 mm/s to 6 m/s (7.9 in/s to 19.7 ft/s)
Operational Range: Up to 3 m H (9.8 ft)
Accuracy: The greater of ±0.5% or 50 mm/s (2 in/s)
Optimal Installation: Install at an angle of 45° in line with the flow. More information is provided within the manual — see the ‘Locating
the MicroFlow sensor’ section
Max. Channel Width Per
Sensor: 1.5 m (4.9 ft)
Radar: K-Band (ISM)
Transmitter Power: <15 dBm
Beam Width: 20° inclusive
OUTPUTS
Communication: RS485 and Modbus RTU
Compatibility with Pulsar
Controllers: Integrates with FlowCERT or Ultimate