Electronics Enclosure: NEMA4X (IP66) polycarbonate with clear, shatterproof cover
Accuracy: ±0.25% of Range or 2 mm (0.08 in) whichever is greater
Repeatability and Linearity: ±0.1%
Display: White, backlit matrix – displays upstream, downstream, and differential level, open channel flow and totalizer, relay
states, operating mode, and calibration menu
Programming: Built-in 5-key calibrator with English, French, or Spanish language selection
Power Input: 100-240 V AC 50/60 Hz (see Options), 3 W maximum (with standard features)
Analog Output: Three Isolated 4-20mA (upstream and downstream level (or open channel flow) and differential level, 1 kΩ load maximum
Control Relays: Qty 2, rated 5 A SPDT, programmable for level control, differential control, or flow proportional pulse
Operating Temp(Electronics): -20 °C to +60 °C (-5 °F to +140 °F)
Approximate Shipping
Weight: 6.8 kg (15 lb)
TRANSDUCER SPECIFICATIONS
Standard Sensor: Includes two PZ15 ultrasonic sensor
Maximum Range: 4.6 m (15 ft) with standard PZ15 sensor
Deadband (Blanking): Programmable, Minimum 203.2 mm (8 in)
Beam Angle: 8°
Operating Frequency: 92 kHz
Exposed Materials: PVC
Operating Temperature: -40 °C to 65 °C (-40 °F to 150°F)
Temperature Compensation: Temperature probe inside the level sensor for high accuracy in changing temperatures
Sensor Cable: RG62AU coaxial, 7.6 m (25 ft) standard length (See Options)
POPULAR OPTIONS
Sensors: 9.7 m (32 ft) measurement range / Intrinsically Safe models
Sensor Cable: 15.2 m (50 ft) or 30.5 m (100 ft) RG62AU coaxial continuous from the sensor, or splice up to 152.4 m (500 ft) with
optional JB Watertight NEMA4 steel with connection terminal strip
Power Input: 9-32 V DC
Extra Control Relays: 4 additional (6 total) rated 5 A SPDT
Data Logger: 2 million point logger with USB output and Windows software – 3 channel logging (A & B sensors plus Differentialor Open Channel flow)