: General Specifications
Weight : 700g (1.5 lbs)
: Dimensions
Wall Mount : 150 mm x 130 mm x 63.5 mm (5.9 in x 5.1 in x 2.5 in)
Fascia Mount : 160 mm x 180 mm x 63 mm (6.3 in x 7.07 in x 2.5 in)
Enclosure Material/Description : Polycarbonate, flame resistant to UL94-V0
Cable Entry Detail : 3 x M20 glands
Transducer Cable Extensions : 3-core Screened
IP Rating : IP67/NEMA 4X for wall mount IP64 for fascia mount
Operating Temperature (Electronics) : -20 ºC to +45 ºC (-4 ºF to +113 ºF)
Accuracy : 0.25% of the measured range or 6mm (whichever is greater) +/- 2 mm (0.079 in) for dBR16 mmWAVE RADAR
Resolution : 0.1% of the measured range or 2 mm (0.079 in); whichever is greater
Analog Output : Isolated floating output (to 150 V) of 4-20mA or 0-20mA into 1 kΩ; user-programmable and adjustable
Volt Free Contacts, Number, and Rating : 3 x SPCO isolated relays, rated at 5 A at 250 V AC and 1 Solid-state SPNO isolated relay, rated 30 V at 100 mA, suitable for pulse counter applications
: Options
Wall mount : For permanent installations, Ultra 4 can be mounted to a nearby wall
Fascia mount : For permanent installations, Ultra 4 can be fascia mounted for easy integration with panels
Communications : RS485 Modbus (opto-isolated)
Profibus and Data Logging Option – V1 (opto-isolated)
HART Communication
Adaptor Plates : Adaptor plates available for easy replacements within panels